Author(s): Falconer Hall P, Blackadder-Coward J, Pynn H

INTRODUCTION: Heat illness among the UK Armed Forces is usually exertional, and therefore preventable, yet the incidence has not reduced since 2011. JSP 539 explicitly states that wet bulb globe temperature (WBGT) should be measured 'at the location of greatest heat risk', not 'that of most convenience'. A handheld WBGT tracker used at point-of-exertion could reduce this incidence if proven to be as accurate as the current in-service device. METHODS: Longitudinal observational comparison and equipment feasibility study of the Kestrel 5400 and QUESTemp 34 (QT-34) in worldwide firm base and deployed UK Armed Forces locations. The locations chosen were Kenya, South Sudan, Belize, Tidworth, Aldershot and Brecon. Paired data points of WBGT readings were collected from November 2017 to August 2018 in all weather conditions. RESULTS: WBGT readings were comparable between the QT-34 and Kestrel 5400 across the UK and overseas. In addition, there was no change in accuracy between readings taken from the Kestrel 5400 when tripod-mounted and handheld. The Kestrel was easy to set up and far less susceptible to resupply or power supply limitations, as it requires no user input for wet bulb temperature, and runs on AA batteries. CONCLUSION: This equipment feasibility study has shown that the Kestrel 5400 gives an acceptable accuracy and is easier to use than the QT-34. The authors recommend that the Kestrel 5400 is introduced as an adjunct to the QT-34, and its use within the military setting monitored through ongoing comparative data collection in a large-scale proof-of-concept study.

DOI: https://dx.doi.org/10.1136/bmjmilitary-2020-001551