2022

Author(s): Wei N, Zheng WX, Zhang N, Zhao SK, Zhai YC, Yang L

The study aims to investigate the thermal comfort requirements in residential buildings and to establish an adaptive thermal comfort model in the cold zone of China. A year-long field study was conducted in residential buildings in Xi'an, China. A total of 2069 valid questionnaires, along with indoor environmental parameters were obtained. The results indicated occupants' thermal comfort requirements varied with seasons. The neutral temperatures were 17.9, 26.1 (highest), 25.2, and 17.4 degrees C (lowest), and preferred temperatures were 23.2, 25.6 (highest), 24.8, and 22.4 degrees C (lowest), respectively for spring, summer, autumn, and winter. The neutral temperature and preferred temperature in autumn are close to the neutral temperature in summer, while the neutral temperature and preferred temperature in spring are close to that in winter. Besides, the 80% and 90% acceptable temperature ranges, adaptive thermal comfort models, and thermal comfort zones for each season were established. Human's adaptability is related to his/her thermal experience of the current season and the previous season. Therefore, compared with the traditional year-round adaptive thermal comfort model, seasonal models can better reflect seasonal variations of human adaptation. This study provides fundamental knowledge of the thermal comfort demand for people in this region.

DOI: https://dx.doi.org/10.1007/s11771-022-5075-9