Author(s): Cheung PK, Jim CY

The sub-divided unit (SDU) is the major type of substandard housing in Hong Kong. This study monitored the microclimatic conditions in eight SDUs for 24 h in summer. The mean CO2 concentration (1012 mg/m(3)) under natural ventilation was much higher than the outdoor level (similar to 410 mg/m(3)), suggesting that ventilation was ineffective in most SDUs. The mean predicted mean vote (PMV) was 1.7 (warm), corresponding to 75% predicted percentage dissatisfied (PPD). None of the SDUs was thermally acceptable (PPD < 20%) at any time in the monitoring period. If the adaptive thermal comfort standard was considered, the acceptable temperature range would be between 23.4 degrees C and 30.4 degrees C in operative temperature and the thermally acceptable time would be 47%. Larger openable window size, larger external wall area and poor ventilation significantly contributed to higher maximum indoor air temperature.

DOI: https://dx.doi.org/10.1080/23744731.2020.1855934